Features
- Meets API 670 External Mounting Specifications
- Quick Disconnect Coupling
- Removal without Re-Gapping
- Fits 4 Probe Sizes
- IP66 Rated, NEMA 4 Raintight
- 316 Stainless Steel Probe Holder
- Explosionproof Cast Aluminum Housing
- Four 3/4" NPT Conduit Hubs
The CMCP801QD Quick Disconnect Proximity Probe Holder is designed for externally mounting proximity probes as described and recommended by API670. External (through the case) mounting allows for easy removal , inspection and adjustment of the proximity probe gap voltage. The CMCP801QD comes with a standard insertion length of 9" (228.6mm) and has an adjustment range of +/-1.0" (+-25.4mm), custom stinger lengths are available on request for application which require a longer insertion depth. The Quick Disconnect coupling allows the probe to be removed without having to re-gap the probe, making to easy to troubleshoot the proximity probe system and quickly perform routine calibration checks.