Features
  • Lithium-Ion Battery Powered with Smart Charger
  • >80+ Hours of Runtime
  • Calibrated Acceleration, Velocity and Displacement Outputs
  • BNC Female Output Connector
  • Peak to Peak and RMS Selectable
  • 318 Hz Fixed Signal Frequency
  • 10 Fixed AC Vibration Amplitude Selections plus Variable Output
  • 10 Fixed DC Gap Selections plus Variable Output
  • Works with both +24 and -24 VDC Powered Systems
  • ±10.0 VDC Bias for Accelerometers and Proximity Systems
The CMCP-TKSG Field Signal Generator is a must have for engineers and technicians who perform installation, maintenance, troubleshooting, and verification of calibration on vibration monitoring systems. The battery powered CMCP-TKSG simulates a fixed frequency acceleration, velocity or displacement signal as well as DC voltages for gap/position monitors. The amplitude of the signal can be adjusted in 10 pre-defined increments or manually adjusted using the variable output setting. The CMCP-TKSG produces a +/-10VDC bias/gap voltage to satisfy OK circuits and offers over 80 hours of runtime on its internal rechargeable lithium-ion battery pack.
CMCP-TKSG Data SheetCMCP-TKSG Manual
AC Voltage Presets: 0.05, 0.10, 0.15, 0.20, 0.25, 0.50, 1.0, 1.5, 2.0 & 2.5 (RMS/Peak)
AC Variable Range: 0.0 to 2.50 VAC
Frequency: 318 Hz ±0.5% Fixed
Units: RMS or Peak (Selectable)
Bias/Gap Voltage: +10VDC or -10VDC (Selectable)
DC Voltage Presets: ±0.0, 2.0, 4.0, 6.0, 8.0, 10.0, 12.0, 14.0, 16.0, 18.0 & 20.0
DC Variable Range: ±0.0 to 20.0 VDC
RMS Accuracy: ±2% @ 22°C After 5 Minute Warmup
Peak-Peak Accuracy: ±3% @ 22°C After 5 Minute Warmup
DC Output Accuracy ±1% @ 22°C
Battery: Lithium Ion (25.9VDC, 3200mAh)
Battery Life: >80 Hours @ 35 mA
Dimensions: 5.9”x3.1”x2.5” (150x80x64 mm)
Weight: 2.5 lbs. (1.13kg)