CMCP515 24 VDC Power Supply, 110/220 VAC

$
Choose your options:
CMCP515 mA Output(required):
Product Code: CMCP515
Features
  • 4 Current Output Sizes
  • Use for +24 or -24 VDC
  • UL, EN, CSA, CB Scheme
  • NEC Class 2
  • Hazardous Location Class 1 Div. 2
  • Universal Input (85 to 264 VAC, 47-63 Hz)
  • Short Circuit and Overload Protected
  • DIN Rail Mounted & Small Size
The CMCP515 Series Power Supplies have a 24 VDC Output and are DIN Rail mounted. They are recommended for use with the CMCP500 and CMCP420VT Series Transmitters and Monitors as well as -24 VDC Proximity Probe Systems. No de-rating or heat-sinking is required, and the output is short circuit protected. If redundant supplies are required the CMCP515-RDNT may be used. If establishing both a +24 VDC and -24 VDC Power Scheme for Proximity Probe Systems please review STI's Tech Note 102 'Powering -24 VDC Eddy Probes' under Downloads.

At STI Vibration Monitoring, our selection of power supplies includes the CMCP515 24 VDC Power Supply, designed to accommodate a wide range of applications with its 110/220 VAC input. This power supply features a reliable 24 VDC output and is DIN rail mounted for easy installation, eliminating the need for de-rating or heat-sinking. As leaders in vibration monitoring and machine protection systems, we take pride in manufacturing our products right here in the U.S., ensuring the highest quality standards. Since 1989, we have been committed to providing our customers with high-quality equipment and are known for offering the best warranties in the industry. Trust STI Vibration Monitoring for reliable power solutions that support your monitoring needs.
CMCP515-0625: CMCP515-1250: CMCP515-2080: CMCP515-4200:
CMCP515 Power Supply Data SheetCMCP515 Power Supply Data SheetCMCP515 Power Supply Data SheetCMCP515-4200 Power Supply Data Sheet

Tech Note 102 Powering -24 VDC Eddy Probes


Electrical Specifications:
  • Input Voltage: 85-264 VAC, 47-63 Hz.
  • Output Voltage: 24-28 VDC
  • Polarity: Floating, Either Positive or Negative Terminal May Be Grounded
  • Short Circuit, Overload and Open Circuit Protection
Environmental Specifications:
  • Operating Temp.: -10°C to +70°C (-14°F to +158°F)
  • Storage Temp.: -25°C to +85°C (-13°F to +185°F)
  • Relative Humidity: 0-95% Non-Condensing
  • NEC Class 2
  • Hazardous Area Approvals Class 1, Division 2
World Wide Approvals (See Data Sheet)